We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Industrial steel plate blower.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Industrial steel plate blower - List of Manufacturers, Suppliers, Companies and Products

Industrial steel plate blower Product List

1~4 item / All 4 items

Displayed results

SDG Corporation "2P・4P Motor"

Custom-made motors tailored to customer specifications, starting from just one unit!

SDG Corporation's "2P・4P Motor" leverages our unique "one-person-one-unit production method" to provide customized specifications based on customer requests, starting from a single unit, with optimal delivery times. This product is compatible with inverter insulation enhancement and can achieve heat resistance classes up to B and F. 【Features】 ■ Multi-variety, small-lot production system ■ Responsive to customer needs ■ Optimal delivery times For more details, please refer to the catalog or feel free to contact us. #HeatCountermeasures #AirflowAnalysis #ExplosionProof

  • Other motors

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Food Manufacturing Industry

Introduction of a case where the installation of equipment improved the steam exhaust of the sterilizer.

We would like to introduce a case of implementing local exhaust equipment in the food manufacturing industry. In the sterilization process of food containers, steam was generated and duct piping was installed to exhaust it outside. However, due to insufficient exhaust volume, we were struggling to effectively expel the steam. By repurposing the existing duct and adding a stainless steel blower, we were able to resolve the issue of steam leakage around the sterilizer. 【Case Summary】 ■ Equipment Introduced: AH-H22GHT-H113 ■ Background of Implementation - There was insufficient exhaust volume, making it difficult to effectively expel steam. ■ Improvements Made - The issue of steam leakage around the sterilizer was resolved. *For more details, please refer to the related links or feel free to contact us.

  • Other air conditioning equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Automotive Parts Manufacturing <Improvement of Ceiling Temperature>

We would like to introduce a case where the temperature of the ceiling was able to be reduced by 5°C!

We would like to introduce a case where the temperature of the ceiling was improved in automotive parts manufacturing. There was a problem where the heat from the carburizing furnace could not be ventilated properly and became trapped in the ceiling, resulting in very high temperatures. By using a wind racer to direct the blown heat towards the opposite window, we were able to exhaust the heat outside and reduce the ceiling temperature from 48.5°C to 43.5°C, a decrease of 5°C. 【Case Overview】 ■ Background - The heat from the carburizing furnace could not be ventilated properly and became trapped in the ceiling. - The ceiling temperature was very high. ■ Improvement Details - Used a wind racer to direct the blown heat towards the opposite window and exhaust it outside. - Successfully reduced the ceiling temperature by 5°C (from 48.5°C to 43.5°C). *For more details, please refer to the PDF document or feel free to contact us.

  • Other environmental equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Chemical Product Manufacturing Plant

Introduction of a dust-blowing system for release agent booths! A case study showcasing how electricity costs were saved.

We would like to introduce a case where our company implemented equipment for blowing away debris in the release agent booth at a finished product manufacturing plant. In this plant, on the manufacturing line for automotive interior materials (polyurethane), they were reducing the defect rate by blowing away polyurethane debris with air blow (compressor) before applying the release agent. After the equipment was introduced, switching from compressor air to a blower resulted in energy savings, allowing for a reduction in electricity costs. [Case Overview] ■ Background of Implementation - On the manufacturing line for automotive interior materials, they were reducing the defect rate by blowing away polyurethane debris with air blow before applying the release agent. ■ Improvements Made - Energy savings were achieved by switching from compressor air to a blower. - Electricity costs were reduced. *For more details, please refer to the PDF document or feel free to contact us.

  • Other environmental equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.